Miroslav Lichvar
2018-05-14 07:44:07 UTC
I've not yet attempted to figure out how to measure the delta between the
two firewall boxes, and the two desktop boxes.
That will probably require directly connected NICs with HWtwo firewall boxes, and the two desktop boxes.
timestamping and/or each machine having a PPS refclock.
For my purposes, the clocks are "close enough". It's interesting, though,
that the chronyd services on the two client boxes both prefer the chronyd
source over the old NTP source.
That's most likely due to a smaller root dispersion reported by thethat the chronyd services on the two client boxes both prefer the chronyd
source over the old NTP source.
chronyd server. ntpd by default increases the dispersion by 15 ppm.
In chronyd it depends on collected statistics and it is usually
smaller than 15 ppm. The minimum dispersion rate can be configured
with the maxclockerror option.
--
Miroslav Lichvar
--
To unsubscribe email chrony-users-***@chrony.tuxfamily.org
with "unsubscribe" in the subject.
For help email chrony-users-***@chrony.tuxfamily.org
with "help" in the subject.
Trouble? Email ***@chrony.tuxfamily.org.
Miroslav Lichvar
--
To unsubscribe email chrony-users-***@chrony.tuxfamily.org
with "unsubscribe" in the subject.
For help email chrony-users-***@chrony.tuxfamily.org
with "help" in the subject.
Trouble? Email ***@chrony.tuxfamily.org.